GENERATOR/CHARGING SYSTEM
GENERATOR TROUBLESHOOTING
No or low AC output
Check that the output indicator (green) is ON.
OFF
ON
Go to page 8-4
Check that the engine speed is normal.
Engine speed: 5,500 – 6,000 min
-1
(rpm) with Eco-
Throttle switch OFF.
Normal
Abnormal
Perform "THROTTLE CONTROL SYSTEM
TROUBLESHOOTING" (page 7-2).
No voltage
Low voltage
Remove the stator (page 8-10).
Check the harness between the inverter unit and
stator for an open or short circuit.
If it is normal, replace the stator.
Replace the rotor (page 8-10).
Normal
Replace the inverter unit (page 8-9).
Gr
P
Remove the control panel (page 8-6).
Disconnect the generator 5P connector from the
inverter unit.
Pull the recoil starter and measure the sub winding
AC voltage.
Terminal number: 4 – 5
Voltage: 1.0 – 2.0 VAC