15-11
dummyhead
dummyhead
CYLINDER BLOCK
CONNECTING ROD BIG END SIDE
CLEARANCE
Measure the clearance between the connecting rod big
end and crankshaft using a feeler gauge.
If the measurement is more than the service limit,
replace the connecting rod (page 15-7) and recheck the
clearance.
If the clearance is still more than the service limit with
the new connecting rod, replace the crankshaft.
CONNECTING ROD SMALL END I.D.
Measure the connecting rod small end I.D.
If the measurement is more than the service limit,
replace the connecting rod.
CONNECTING ROD BIG END I.D.
Apply oil to the connecting rod bolts [1] threads and
seating surface.
Set the connecting rod cap [2] to the connecting rod [3]
and tighten the connecting rod bolts to the specified
torque.
Measure the connecting rod big end I.D.
If the measurement is more than the service limit,
replace the connecting rod.
STANDARD:
0.1 – 0.6 mm (0.004 – 0.024 in)
SERVICE LIMIT: 0.8 mm (0.031 in)
STANDARD:
10.006 – 10.017 mm
(0.3939 – 0.3944 in)
SERVICE LIMIT: 10.050 mm (0.3957 in)
TORQUE: 5.9 N·m (0.6 kgf·m, 4.4 lbf·ft)
STANDARD:
15.000 – 15.011 mm
(0.5906 – 0.5910 in)
SERVICE LIMIT: 15.040 mm (0.5921 in)
[1]
[2]
[3]
Summary of Contents for EU10iT1
Page 15: ...MEMO dummyhead dummyhead ...
Page 33: ...MEMO dummyhead dummyhead ...
Page 47: ...MEMO dummyhead dummyhead ...
Page 53: ...MEMO dummyhead dummyhead ...
Page 55: ...6 2 dummyhead dummyhead FUEL SYSTEM FUEL SYSTEM TOOL Float level gauge 07401 0010000 ...
Page 67: ...MEMO dummyhead dummyhead ...
Page 100: ...12 1 12 dummytext 12 MUFFLER MUFFLER REMOVAL INSTALLATION 12 2 ...
Page 115: ...MEMO dummyhead dummyhead ...