Output Function Summary Table
– This table shows all functions for the logical outputs
(terminals [11], [12] and [AL]) at a glance. Detailed descriptions of these functions, related
parameters and settings, and example wiring diagrams are in “Using Intelligent Output
Terminals” on page 36.
Output Function Summary Table
Option
Code
Terminal
Symbol
Function Name
Description
ON
When the inverter is in Run Mode
00
RUN Run
Signal
OFF
When the inverter is in Stop Mode
ON
When output to motor is at the set frequency
01
FA1 Frequency
Arrival
Type
1–Constant Speed
OFF
When output to motor is OFF, or in any
acceleration or deceleration ramp
ON
When output to motor is at or above the set freq,
even if in accel (
C042
) or decel (
C043
) ramps
02
FA2 Frequency
Arrival
Type
2–Over frequency
OFF
When output to motor is OFF,
or at a level below the set frequency
ON
When output current is more than the set
threshold (
C041
) for the overload signal
03
OL Overload
Advance
Notice Signal 1
OFF
When output current is less than the set threshold
for the deviation signal
ON
When PID error is more than the set threshold for
the deviation signal
04
OD Output
Deviation
for PID Control
OFF
When PID error is less than the set threshold for
the deviation signal
ON
When an alarm signal has occurred and has not
been cleared
05
AL Alarm
Signal
OFF
When no alarm has occurred since the last
cleaning of alarm(s)
ON
When output to motor is at the set frequency,
during accel (
C042
) and decel (
C043
).
06
FA3 Frequency
Arrival
Type
3–Set frequency
OFF
When output to motor is OFF,
or is not at a level of the set frequency
ON
Estimated motor torque exceeds
the specified level
07
OTQ Over/under
Torque
Signal
OFF
Estimated motor torque is lower than
the specified level
ON
Inverter is in Undervoltage
09
UV Undervoltage
OFF
Inverter is not in Undervoltage
ON
Torque limit function is executing
10
TRQ
Torque Limited Signal
OFF
Torque limit function is not executing
ON
Total running time of the inverter exceeds
the specified value
11
RNT Run
Time
Expired
OFF
Total running time of the inverter does not exceed
the specified value
ON
Total power ON time of the inverter exceeds
the specified value
12
ONT
Power ON time Expired
OFF
Total power ON time of the inverter does not
exceed the specified value
ON
Accumulated thermal count exceeds
the
C061
set value
13
THM Thermal
Warning
OFF
Accumulated thermal count does not exceed the
C061
set value
ON
Output for brake release
19
BRK
Brake Release Signal
OFF
No action for brake
ON
Brake error has occurred
20
BER
Brake Error Signal
OFF
Brake performance is normal