59
Intelligent Terminal Functions
“C” Function
Defaults
Func.
Code
Name
Description
Run
Mode
Edit
Initial data
Units
C001
Input [1] function
Select input terminal [1] function,
68 options (see next section)
U
00
[FW]
−
C002
Input [2] function
Select input terminal [2] function,
68 options (see next section)
U
01
[RV]
−
C003
Input [3] function
[GS1 assignable]
Select input terminal [3] function,
68 options (see next section)
U
02
[CF1]
−
C004
Input [4] function
[GS2 assignable]
Select input terminal [4] function,
68 options (see next section)
U
03
[CF2]
−
C005
Input [5] function
[PTC assignable]
Select input terminal [5] function,
68 options (see next section)
U
09
[2CH]
−
C006
Input [6] function
Select input terminal [6] function,
68 options (see next section)
U
18
[RS]
−
C007
Input [7] function
Select input terminal [7] function,
68 options (see next section)
U
13
[USP]
−
C011
Input [1] active state
U
00
−
C012
Input [2] active state
U
00
−
C013
Input [3] active state
U
00
−
C014
Input [4] active state
U
00
−
C015
Input [5] active state
U
00
−
C016
Input [6] active state
U
00
−
C017
Input [7] active state
Select logic conversion, two option
codes:
00
…
normally open [NO]
01
…
normally closed [NC]
U
00
−
C021
Output [11] function
[EDM assignable]
U
01
[FA1]
−
C022
Output [12] function
48 programmable functions
available for logic (discrete) outputs
(see next section)
U
00
[RUN]
−
C026
Alarm relay function
48 programmable functions
available for logic (discrete) outputs
(see next section)
U
05
[AL]
−
C027
[EO] terminal selection
(Pulse/PWM output)
13 programmable functions:
00
…
Output frequency (PWM)
01
…
Output current (PWM)
02
…
Output torque (PWM)
03
…
Output frequency (Pulse train)
04
…
Output voltage (PWM)
05
…
Input power (PWM)
06
…
Electronic thermal load ratio
(PWM)
07
…
LAD frequency (PWM)
08
…
Output current (Pulse train)
10
…
Heat sink temperature (PWM)
12
…
General output (PWM)
15
…
Pulse train input monitor
16
…
Option(PWM)
U