71
Motor Constants Functions
“H” Function
Defaults
Func.
Code
Name
Description
Run
Mode
Edit
Initial data
Units
H001
Auto-tuning selection
Three option codes:
00
…
Disabled
01
…
Enabled with motor stop
02
…
Enabled with motor rotation
U
00
−
H002
Motor constant selection
U
00
−
H202
Motor constant selection,
2
nd
motor
Four option codes:
00
…
Hitachi standard motor
02
…
Auto tuned data
U
00
−
H003
Motor capacity
U
kW
H203
Motor capacity,
2
nd
motor
Eleven selections:
0.1/0.2/0.4/0.75/1.5/2.2/3.7/
5.5/7.5/11/15/18.5
U
Specified by
the capacity
of each
inverter
model
kW
H004
Motor poles setting
U
4 poles
H204
Motor poles setting,
2
nd
motor
Four selections:
2 / 4 / 6 / 8 / 10
U
4 poles
H005
Motor speed response
constant
9
100.
−
H205
Motor speed response
constant, 2
nd
motor
Set range is 1 to 1000
9
100.
−
H006
Motor stabilization constant
9
100.
−
H206
Motor stabilization
constant, 2
nd
motor
Motor constant (factory set),
range is 0 to 255
9
100.
−
H020
Motor constant R1
(Hitachi motor)
U
ohm
H220
Motor constant R1,
2
nd
motor (Hitachi motor)
0.001~65.535 ohms
U
ohm
H021
Motor constant R2
(Hitachi motor)
U
ohm
H221
Motor constant R2,
2
nd
motor
(Hitachi motor)
0.001~65.535 ohms
U
ohm
H022
Motor constant L
(Hitachi motor)
U
mH
H222
Motor constant L,
2
nd
motor
(Hitachi motor)
0.01~655.35mH
U
mH
H023
Motor constant I0
(Hitachi motor)
U
A
H223
Motor constant I0,
2
nd
motor
(Hitachi motor)
0.01~655.35A
U
A
H024
Motor constant J
(Hitachi motor)
U
kgm
2
H224
Motor constant J,
2
nd
motor
(Hitachi motor)
0.001~9999 kgm
2
U
Specified by
the capacity
of each
inverter
mode
kgm
2
H030
Motor constant R1
(Auto tuned data)
U
ohm
H230
Motor constant R1,
2
nd
motor
(Auto tuned data)
0.001~65.535 ohms
U
ohm
H031
Motor constant R2
(Auto tuned data)
0.001~65.535 ohms
U
Specified by
the capacity
of each
inverter
mode
ohm