Troubleshooting code
Failure level
Recovery action
TRSTNA000001
INFO
Output when the Web
Application server starts.
To confirm that the Web
Application Server started
normally, match it to the
troubleshooting code and check
that TRSTNA000002 is output.
TRSTNA000002
INFO
Output when the start of the
Web Application server is
completed.
TRSTNA000003
ERROR
The Web Application server
failed to start.
Select the appropriate storage
system from the
Storage
Device List
, stop it, and then
restart it.
If it does not recover, restart
the SVP.
If it does not recover after
restarting the SVP, set up
Device Manager - Storage
Navigator again.
TRSTNA000004
INFO
Output when the Web
Application server stops.
TRSTNA000005
INFO
Output when the Web
Application server stops
completely.
TRSTNA000006
ERROR
An error occurred by stopping
the Web Application server.
Restart the SVP.
If it does not recover after
restarting the SVP, set up
again.
TRSTNA000007
WARN
The Device Manager - Storage
Navigator service stopped
unexpectedly, and then it is
restarting.
If the condition does not
change within three minutes,
stop the storage system by
Storage Device List and restart
it.
If it does not recover, restart
the SVP.
356
Troubleshooting the storage system
Service Guide for VSP Gx00 and VSP Fx00 Models
Summary of Contents for Virtual Storage Platform F400
Page 4: ...4 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 22: ...22 Preface Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 106: ...106 Replacing storage system components Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 140: ...140 Replacing a fan Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 146: ... CBLM CBLH 146 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 160: ...160 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 198: ...6 Click Block 198 Replacing cache memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 250: ...250 Replacing a SAS cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 260: ...260 Replacing cache flash memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 268: ...268 Replacing a LAN blade Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 278: ...278 Replacing a backup module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 284: ...284 Replacing a PCIe module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 296: ...296 Replacing a PCIe cable connector Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 302: ...302 Replacing a PCIe cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 312: ...312 General maintenance Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 397: ...Warning labels on the storage system 397 Service Guide for VSP Gx00 and VSP Fx00 Models ...