![Hitachi Virtual Storage Platform F400 Service Manual Download Page 45](http://html.mh-extra.com/html/hitachi/virtual-storage-platform-f400/virtual-storage-platform-f400_service-manual_143300045.webp)
Note:
Removing a controller can cause the
POWER
,
READY
,
WARNING
, and
ALARM
LEDs on the front panel to go off. These LEDs return to their on state
after the storage system recovers from the controller replacement.
CBLH front panel without bezel
The following table describes the definitions of the CBLH controller front panel
LEDs.
Number
Item
Description
1
POWER ON/OFF (main switch)
Powers the storage system.
2
POWER
,
READY
,
WARNING
, and
ALARM
LEDs
See the previous table.
3
Controllers
Controller 1 (bottom) and
Controller 2 (top).
4
Backup module
N/A
5
BACKUP
LED
Green: Power restoration in
progress following power
outage.
Fast blink green: Restoring.
Slow blink green: Restoring, or
sequential shutdown in
progress.
6
Cache flash memory
N/A
7
ALM
LED (for cache flash
memory)
Red: Cache flash memory can
be removed.
8
CTL ALM
LED
Red: Controller can be
removed.
Blink red: Failure with the
power supply unit of the
controller.
Hardware description
45
Service Guide for VSP Gx00 and VSP Fx00 Models
Summary of Contents for Virtual Storage Platform F400
Page 4: ...4 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 22: ...22 Preface Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 106: ...106 Replacing storage system components Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 140: ...140 Replacing a fan Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 146: ... CBLM CBLH 146 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 160: ...160 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 198: ...6 Click Block 198 Replacing cache memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 250: ...250 Replacing a SAS cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 260: ...260 Replacing cache flash memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 268: ...268 Replacing a LAN blade Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 278: ...278 Replacing a backup module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 284: ...284 Replacing a PCIe module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 296: ...296 Replacing a PCIe cable connector Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 302: ...302 Replacing a PCIe cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 312: ...312 General maintenance Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 397: ...Warning labels on the storage system 397 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 405: ...Warning labels on the storage system 405 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 412: ...412 Warning labels on the storage system Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 417: ...Service Guide for VSP Gx00 and VSP Fx00 Models ...