19.
Route the cables appropriately.
Note:
The SAS cable does not have to be routed when connecting
the DW-F800-SCQ1HA SAS adapter.
20.
At the
Replace Disk Board
window, click
Restore
.
A progress bar shows the replacement status.
21.
When the progress bar goes away and the completion message appears,
click
Close
.
22.
Click the
DKBs
tab, and then check that the back end module whose
SAS cable you replaced is
Normal
.
23.
Log out and close the
Maintenance Utility
window.
Replacing SAS cables on a drive tray
Replacing SAS cables for a drive tray requires you to block an ENC before
replacing the cables.
The following procedure describes how to replace SAS cables connected to a
drive tray. Wear a wrist strap connected to the storage system to prevent
part failures caused by static electricity. Do not remove the wrist strap until
you finish the procedure.
Procedure
1.
Start the maintenance utility.
2.
Click
Hardware > Drive Box
.
3.
In the
Drive Box
window, click the
ENCs
tab.
4.
To display the most recent status of the ENC, click
Refresh
.
Replacing a SAS cable
245
Service Guide for VSP Gx00 and VSP Fx00 Models
Summary of Contents for Virtual Storage Platform F400
Page 4: ...4 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 22: ...22 Preface Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 106: ...106 Replacing storage system components Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 140: ...140 Replacing a fan Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 146: ... CBLM CBLH 146 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 160: ...160 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 198: ...6 Click Block 198 Replacing cache memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 250: ...250 Replacing a SAS cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 260: ...260 Replacing cache flash memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 268: ...268 Replacing a LAN blade Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 278: ...278 Replacing a backup module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 284: ...284 Replacing a PCIe module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 296: ...296 Replacing a PCIe cable connector Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 302: ...302 Replacing a PCIe cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 312: ...312 General maintenance Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 397: ...Warning labels on the storage system 397 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 405: ...Warning labels on the storage system 405 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 412: ...412 Warning labels on the storage system Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 417: ...Service Guide for VSP Gx00 and VSP Fx00 Models ...