Message ID
Description
Recovery Action
Storage Navigator cannot
start.
21041-006005
Starting the Storage
Device List caused the
error, and the Storage
Device List cannot start.
Failed to connect to the Supervisor
service (
DKCMan/MAPPAppServer/
MAPPWebServer
). From the Windows start
menu, click Control Panel > System and
Security > Administrative Tools >
Services, and confirm that the DKCMan,
MAPPAppServer, and MAPPWebServer
services started. Start the Storage Device
List again.
If the status of DKCMan, MAPPAppServer,
and MAPPWebServer did not start, right-
click the service and click Start, or reboot
the SVP.
21513-008004
[Warning] was displayed in
the storage system icon.
Clicking [Warning]
displayed "21513-008004"
in the
Status
field.
Another SVP is connected to the storage
system.
Stop the services of the storage system
running on the PC whose IP address is
shown in the troubleshooting code
TRCOMM000004 of the background
service log.
21513-008005
[Warning] was displayed in
the storage system icon.
Clicking [Warning]
displayed "21513-008005"
in the
Status
field.
The IP address for each CTL configured in
the
Add System
window and the CTL
number set for GUM are not identical.
Correct the IP address setting for each
controller in the
Storage Device List
window.
21513-008006
[Warning] was displayed in
the storage system icon.
Clicking [Warning]
displayed "21513-008006"
in the
Status
field.
The storage system model configured in
the
Add System
window is different than
the model that was specified during
setup.
Delete the storage system from the
Storage Device List
and re-register the
storage system with the correct model.
21513-008007
[Warning] was displayed in
the storage system icon.
Clicking [Warning]
displayed "21513-008007"
in the
Status
field.
The Configuration model set in the
Add
System
window is different than the
model that was specified during setup.
Delete the storage system from the
Storage Device List
and re-register the
storage system with the correct Config
model.
21513-008008
[Warning] was displayed in
the storage system icon.
Clicking [Warning]
displayed "21513-008008"
in the
Status
field.
The serial number set in the
Add
System
window and the serial number
set in the storage system are not
identical.
Delete the storage system from the
Storage Device List
and re-register the
storage system with the correct serial
number.
332
Troubleshooting the storage system
Service Guide for VSP Gx00 and VSP Fx00 Models
Summary of Contents for Virtual Storage Platform F400
Page 4: ...4 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 22: ...22 Preface Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 106: ...106 Replacing storage system components Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 140: ...140 Replacing a fan Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 146: ... CBLM CBLH 146 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 160: ...160 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 198: ...6 Click Block 198 Replacing cache memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 250: ...250 Replacing a SAS cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 260: ...260 Replacing cache flash memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 268: ...268 Replacing a LAN blade Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 278: ...278 Replacing a backup module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 284: ...284 Replacing a PCIe module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 296: ...296 Replacing a PCIe cable connector Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 302: ...302 Replacing a PCIe cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 312: ...312 General maintenance Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 397: ...Warning labels on the storage system 397 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 405: ...Warning labels on the storage system 405 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 412: ...412 Warning labels on the storage system Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 417: ...Service Guide for VSP Gx00 and VSP Fx00 Models ...