Replacing the BKMF backup module
Before you begin
• Wear a wrist strap connected to the storage system to prevent part
failures caused by static electricity. Do not remove the wrist strap until you
finish the procedure.
• Confirm that the storage system power is turned on.
• Confirm that the red
STATUS
LED on the backup module to be replaced is
on.
• Use the Dump tool to collect the storage system configuration information.
• Use the maintenance utility to verify the backup module status.
Procedure
1.
Loosen the blue screw that secures the backup module.
2.
Open the lever forward.
3.
Open the lever.
4.
Hold the backup module with both hands, and then pull it out and
remove it.
5.
Hold the latch of the cable connector of the battery to be installed in the
backup module and remove the connector from the socket.
6.
Remove all batteries that are installed.
A maximum of two batteries can be installed.
7.
Loosen the blue screw on the rear side of the new backup module.
8.
Slide the top panel of the new backup module and remove it.
9.
In the new backup module, install all batteries you removed and route
the cables along the groove of the backup module.
If you removed one battery, install the battery in the front (fan side) of
the storage system. Route the cables to avoid bending the cables.
10.
Connect the cable connector to the socket.
11.
Slide the top panel of the backup module and attach it.
12.
Tighten the blue screw on the rear panel of the backup module.
13.
With the lever of the backup module opened forward, insert the new
backup module into the slot.
Replacing a backup module
273
Service Guide for VSP Gx00 and VSP Fx00 Models
Summary of Contents for Virtual Storage Platform F400
Page 4: ...4 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 22: ...22 Preface Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 106: ...106 Replacing storage system components Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 140: ...140 Replacing a fan Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 146: ... CBLM CBLH 146 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 160: ...160 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 198: ...6 Click Block 198 Replacing cache memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 250: ...250 Replacing a SAS cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 260: ...260 Replacing cache flash memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 268: ...268 Replacing a LAN blade Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 278: ...278 Replacing a backup module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 284: ...284 Replacing a PCIe module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 296: ...296 Replacing a PCIe cable connector Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 302: ...302 Replacing a PCIe cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 312: ...312 General maintenance Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 397: ...Warning labels on the storage system 397 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 405: ...Warning labels on the storage system 405 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 412: ...412 Warning labels on the storage system Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 417: ...Service Guide for VSP Gx00 and VSP Fx00 Models ...