performance data for key components of the storage system to enable
diagnostic testing and analysis for customer support.
For more information about the SVP, see the
Service Processor Technical
Reference
.
Service processor description
The SVP runs Windows
®
Embedded Standard 7 operating system, which
provides the same desktop environment look and feel as Windows 7
Professional.
The SVP software application can also be installed on a customer-supplied
server running Windows 7 Professional x64 Service Pack 1, Windows 10
Professional or Enterprise, or Windows Server 2012 or Windows Server 2012
R2. For more information about supported hardware, operating systems and
virtual environments, see the
Service Processor Technical Reference for VSP
Gx00 and VSP Fx00 Models.
• Microsoft Hyper-V Windows Server 2012 R2
• VMware ESXi
• Linux KVM
Note:
This product is also designed for IT power distribution systems with
phase-to-phase voltage.
The SVP provides four RJ-45 ports:
• Two ports connect to the storage system controllers (one port for each
controller).
• One port connects to the IP network of the user.
• One port connects to a user-supplied management console PC.
Three of the four RJ-45 ports (which connect to the controllers and the IP
network) are configured as a bridge. The SVP can be addressed using the
default IP address 192.168.0.15.
In the unlikely event you cannot connect to the SVP using the default IP
address, use the following emergency login:
http://<default SVP IP
address>/dev/storage/<model number><system serial number>/
emergency.do
. For example:
Storage system model number
Storage system serial number
URL
8320004
456789
http://192.168.0.15/dev/
storage/8320004456789/
emergency.do
8340004
456789
http://192.168.0.15/dev/
storage/8340004456789/
emergency.do
74
Hardware description
Service Guide for VSP Gx00 and VSP Fx00 Models
Summary of Contents for Virtual Storage Platform F400
Page 4: ...4 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 22: ...22 Preface Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 106: ...106 Replacing storage system components Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 140: ...140 Replacing a fan Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 146: ... CBLM CBLH 146 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 160: ...160 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 198: ...6 Click Block 198 Replacing cache memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 250: ...250 Replacing a SAS cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 260: ...260 Replacing cache flash memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 268: ...268 Replacing a LAN blade Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 278: ...278 Replacing a backup module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 284: ...284 Replacing a PCIe module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 296: ...296 Replacing a PCIe cable connector Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 302: ...302 Replacing a PCIe cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 312: ...312 General maintenance Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 397: ...Warning labels on the storage system 397 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 405: ...Warning labels on the storage system 405 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 412: ...412 Warning labels on the storage system Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 417: ...Service Guide for VSP Gx00 and VSP Fx00 Models ...