prompt. When completing the tool execution,
zSv_AutoDump.exe
is completed
appears in the command prompt.
5.
At the completion message, close the command prompt.
6.
Under the output destination folder, check that the following files are
created.:
•
hdcp.tgz
is the dump file. If many dump files are output to the
storage system, the SVP free space might be insufficient, and you will
have to move the dump files to a location other than the SVP.
zSv_AutoDump.log
is the dump tool log file. If the dump file was not
created, send this log file to your administrator. Otherwise, delete the
log file.
7.
Exit the command prompt.
Collecting dump files manually
If you cannot use the Dump tool or the Dump tool fails, collect the following
dump files manually.
In the following list:
•
installDir
is the SVP installation directory (for example,
C:\Mapp
).
•
%USERPROFILE%
is the installation login user of the SVP (for example,
C:
\Users\<user name>
).
•
%WINDIR%
is the Windows folder in the system drive (for example,
C:
\Windows
).
<installDir>\wk\supervisor\dkcman\log\*.*
<installDir>\wk\supervisor\dkcman\cnf\*.*
<installDir>\wk\supervisor\rmiserver\log\*.*
<installDir>\wk\supervisor\rmiserver\cnf\*.*
<installDir>\wk\supervisor\sdlist\log\*.*
<installDir>\wk\supervisor\mappiniset\logs\MappIniSet\*.*
<installDir>\wk\supervisor\mappiniset\mpprt\cnf
<installDir>\wk\supervisor\portmanager\logs\PortManager\*.*
<installDir>\wk\supervisor\restapi\data
<installDir>\wk\supervisor\restapi\logs
<installDir>\wk\supervisor\restapi\build.json
<installDir>\wk\supervisor\restapi\version.json
<installDir>\wk\supervisor\system\log\*.log
380
Troubleshooting the storage system
Service Guide for VSP Gx00 and VSP Fx00 Models
Summary of Contents for Virtual Storage Platform F400
Page 4: ...4 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 22: ...22 Preface Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 106: ...106 Replacing storage system components Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 140: ...140 Replacing a fan Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 146: ... CBLM CBLH 146 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 160: ...160 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 198: ...6 Click Block 198 Replacing cache memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 250: ...250 Replacing a SAS cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 260: ...260 Replacing cache flash memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 268: ...268 Replacing a LAN blade Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 278: ...278 Replacing a backup module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 284: ...284 Replacing a PCIe module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 296: ...296 Replacing a PCIe cable connector Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 302: ...302 Replacing a PCIe cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 312: ...312 General maintenance Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 397: ...Warning labels on the storage system 397 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 405: ...Warning labels on the storage system 405 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 412: ...412 Warning labels on the storage system Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 417: ...Service Guide for VSP Gx00 and VSP Fx00 Models ...