Observe the following guidelines:
• If you replaced a drive without blocking it, click
Refresh
in the
Maintenance Utility
window, and then check the status of the
replaced drive.
• When replacing a drive after saving data to a spare drive, the drive
status changes to
Normal
after performing the copy-back operation.
This operation can take up to 12 hours to perform, depending on the
configuration and drive capacity
• If the drive status is
Copy incomplete
, the correction-copy operation
cannot be performed because a copy-processing operation is being
performed in the parity group to which the target drive belongs. If you
are not sure about the restoration method or if the restoration fails,
contact the HDS Support Portal at
https://support.hds.com/en_us/
.
Restoration method: After completing other copy operations, replace
the drive using the drive-replacement procedure. For the drive
replacement, reuse the drive that was removed instead of using a new
drive.
• If the drive status is
Reserved
, the copy-back operation cannot be
performed because more than one copy-processing operation is being
performed in the parity group to which the copy-back source drive of
the target drive belongs. If you are not sure about the restoration
method or if the restoration fails, contact the HDS Support Portal at
https://support.hds.com/en_us/contact-us.html
Restoration method: After completing other copy operations, replace
the drive using the drive-replacement procedure. For the drive
Replacing a drive
119
Service Guide for VSP Gx00 and VSP Fx00 Models
Summary of Contents for Virtual Storage Platform F400
Page 4: ...4 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 22: ...22 Preface Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 106: ...106 Replacing storage system components Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 140: ...140 Replacing a fan Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 146: ... CBLM CBLH 146 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 160: ...160 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 198: ...6 Click Block 198 Replacing cache memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 250: ...250 Replacing a SAS cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 260: ...260 Replacing cache flash memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 268: ...268 Replacing a LAN blade Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 278: ...278 Replacing a backup module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 284: ...284 Replacing a PCIe module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 296: ...296 Replacing a PCIe cable connector Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 302: ...302 Replacing a PCIe cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 312: ...312 General maintenance Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 397: ...Warning labels on the storage system 397 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 405: ...Warning labels on the storage system 405 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 412: ...412 Warning labels on the storage system Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 417: ...Service Guide for VSP Gx00 and VSP Fx00 Models ...