MAINTENANCE
7-108
REPLACE BATTERIES
Your machine has four 12-volts batteries with negative (
−
)
ground.
If one of four batteries in a 24-volt system has failed but
the others are still good, replace all the batteries together
with new ones of the same type. For example, replace a
failed maintenance-free battery with a new mainte-
nance-free battery. Different types of batteries may have
different rates of charge. This difference could overload
one of the batteries and cause it to fail.
IMPORTANT: Do not pull the disconnector lever (1)
down during operation.
NOTE: Ground Disconnector
This machine is equipped with a battery ground
disconnector located outside of engine unit
compartment on the right side. The battery
ground circuit can be disconnected by pulling
disconnector lever (1) down before replacing
the battery, checking the electrical system, or
performing welding work on the machine.
CAUTION: Do not replace the battery in human
strength. Use the crane to replace safely.
M146-01-021
M146-07-062
1
Summary of Contents for EX 3600-6
Page 38: ...SAFETY SIGNS S 29 SS3091469 M146 07 080 ...
Page 40: ...SAFETY SIGNS S 31 SS 410 SS 2835 SS3108517 M18G 01 011 ...
Page 41: ...SAFETY SIGNS S 32 SS 413 M146 01 024 M146 01 025 SS4193223 M146 01 025 ...
Page 42: ...SAFETY SIGNS S 33 SS 449 M146 01 027 SS 710 SS 2836 SS 3091472 SS 2837 ...
Page 43: ...SAFETY SIGNS S 34 MEMO ...
Page 89: ...OPERATOR S STATION 1 46 MEMO ...
Page 107: ...OPERATING THE ENGINE 3 16 MEMO ...
Page 119: ...DRIVING THE MACHINE 4 12 MEMO ...
Page 139: ...OPERATING THE MACHINE 5 20 MEMO ...
Page 166: ...MAINTENANCE 7 27 4 Grouped Grease Fittings 4 Arm Ñ Lubrication Points M146 07 085 4 ...
Page 169: ...MAINTENANCE 7 30 4 Grouped Grease Fittings 4 Arm Ñ Lubrication points M18M 07 036 4 ...
Page 283: ...MAINTENANCE 7 144 MEMO ...
Page 285: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 2 MEMO ...
Page 303: ...SPECIFICATIONS 12 4 MEMO ...