MAINTENANCE
7-9
5. Turn the key switch ON.
6. Remove plugs (6) and (7) on the pipe line to allow the
electric pump to draw oil easily.
Plugs are located at
•
Suction Line: Suction pipe of main pump
•
Return Line: Top of oil cooler
7. Close 2 stop valves (8) on the suction pipes under
the hydraulic oil tank.
8. Turn electric pump (2) switch ON. The pump starts to
draw oil.
9. After drawing oil, turn electric pump (2) switch OFF.
10. Install plugs (6) and (7). Close stop valve (5).
Disconnect suction hose (3) of electric pump (2).
M18M-07-010
M18M-07-008
M18M-07-009
M18M-07-063
M18M-07-064
Main Pump Plugs
Return Line
B
5
6
4
Section B