MAINTENANCE
7-38
Check LED Monitor Signal (on Reserve Tank)
--- check daily
1. Start the engine.
2. Check LED monitor (1) to confirm if the pump
normally works or not. LED monitor (1) signals the
following states in response to operation of pump.
a. Steady: This signal indicates that the Pump #1
only is running and is transferred oil
from the engine oil pan to the reserve
tank.
b. Flashing: This signal indicates that the Pump #1
and #2 are running and oil is being
transferred from the reserve tank to the
engine oil pan.
IMPORTANT: The signal should alternate between
periods of Steady and Flashing so that
required engine oil level is being
maintained on during operation.
NOTE: If the LED monitor does not work, contact your
authorized dealer.
M18M-07-079
From
Reserve
Tank
From
Engine Oil
Pan
Pump #2
Pump #1
1
To Reserve
Tank
To Engine
Oil Pan
Summary of Contents for EX 3600-6
Page 38: ...SAFETY SIGNS S 29 SS3091469 M146 07 080 ...
Page 40: ...SAFETY SIGNS S 31 SS 410 SS 2835 SS3108517 M18G 01 011 ...
Page 41: ...SAFETY SIGNS S 32 SS 413 M146 01 024 M146 01 025 SS4193223 M146 01 025 ...
Page 42: ...SAFETY SIGNS S 33 SS 449 M146 01 027 SS 710 SS 2836 SS 3091472 SS 2837 ...
Page 43: ...SAFETY SIGNS S 34 MEMO ...
Page 89: ...OPERATOR S STATION 1 46 MEMO ...
Page 107: ...OPERATING THE ENGINE 3 16 MEMO ...
Page 119: ...DRIVING THE MACHINE 4 12 MEMO ...
Page 139: ...OPERATING THE MACHINE 5 20 MEMO ...
Page 166: ...MAINTENANCE 7 27 4 Grouped Grease Fittings 4 Arm Ñ Lubrication Points M146 07 085 4 ...
Page 169: ...MAINTENANCE 7 30 4 Grouped Grease Fittings 4 Arm Ñ Lubrication points M18M 07 036 4 ...
Page 283: ...MAINTENANCE 7 144 MEMO ...
Page 285: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 2 MEMO ...
Page 303: ...SPECIFICATIONS 12 4 MEMO ...