Figure 2-5 Face Recognition Terminal Wiring
Note
• The supplied interconnecting cable length is 3.75 m. If you need a longer one, ask our technique
supports or sales and purchase 5.5 m interconnecting cables.
• The suggested inner diameter of the low voltage conduit is larger than 30 mm.
• If you want to bury both of the AC power cord and the low voltage cable at the entrance side,
the two cables should be in separated conduits to avoid interference.
• If more peripherals are required to connect, you should increase the conduit diameter or bury
another conduit for the external cable.
• The external AC power cord should be double-insulated.
• The suggested network cable should be CAT5e or the network cable has better performance.
And the suggested network cable length should be less than 100 m.
2.4 Terminal Description
The lane controller contains master lane controller and slave lane controller, which controls the IR
beams, motor, and other components' work.
2.4.1 Master Control Board Terminal Description
The master lane control board contains interconnecting interfaces, BUS, motor encoder interface,
debugging port, door closed position interface, seven-segment display, strip light interface
(reserved), supercapacitor, power interface, motor drive interface, and DIP switch.
The picture displayed below is the master control board diagram.
DS-K3B501S Series Swing Barrier User Manual
7
Summary of Contents for DS-K3B501S Series
Page 1: ...DS K3B501S Series Swing Barrier User Manual ...
Page 30: ...Entering Wiring Exiting Wiring DS K3B501S Series Swing Barrier User Manual 17 ...
Page 32: ...Figure 2 8 Fire Alarm Module Wiring DS K3B501S Series Swing Barrier User Manual 19 ...
Page 115: ...Figure F 2 Device Command DS K3B501S Series Swing Barrier User Manual 102 ...
Page 116: ...UD18744B ...