Camera Link Line Scan Camera
·
User Manual
39
The event source may differ by camera models.
The strobe signal is used to directly output signal to external devices when the camera’s event
source occurs. When selected event sources occur, one event information will be created, and the
camera will output one strobe signal at the same time. Refer to the table below for detailed event
source description.
Table 8-1
Event Source Description
No. Name
Description
1
Exposure Start Active
The camera outputs signals to external devices when it starts
exposure.
2
Frame Burst Start Active
The camera outputs one I/O edge signal when starting triggering
and acquiring images under Burst mode.
3
Frame Burst End Active
The camera outputs one I/O edge signal when stopping triggering
and acquiring images under Burst mode.
4
Soft Trigger Active
The camera outputs signals to external devices when software
trigger starts.
5
Hard Trigger Active
The camera outputs signals to external devices when hardware
trigger starts.
6
Counter Active
The camera outputs one I/O edge signal when counter output is
enabled.
7
Timer Active
The camera outputs one I/O edge signal when timer output is
enabled.
Regarding Counter and Timer Control, you can refer the table below for details.
Table 8-2
Description of Counter and Timer Control
Parameter
Read/Write
Description
Counter Selector
Read and write
It selects counter source. Counter 0 is available only at
present.
Counter Event Source Read and write
It selects the signal source of counter trigger. It is
disabled by default.