Camera Link Line Scan Camera
·
User Manual
49
9.4 Output Wiring for Type I and Type III Cameras
The I/O signal of type I and type III cameras can be configured as output to trigger other devices.
Here we take the type I camera as an example for introducing the output wiring.
9.4.1 Differential Output Singal
If the camera’s I/O signal is set as the differential output signal, and the wiring is shown below.
OUT A
Line*_P
OUT Ã
Triggered
Device
Camera Power
PWR
Camera Power Ground
GND
Line*_N
Triggered Device
Power Ground
Figure 9-7
Differential Output Wiring
9.4.2 Single-Ended Output Signal
If the triggered device needs a LVTTL level trigger below 3.3 V, and the wiring is shown below.
Line*N
Triggered
Device
Camera Power
PWR
Camera Power Ground
GND
Hang
Line*P
Triggered Device
Power Ground
Signal Line
Figure 9-8
Single-Ended Output Wiring without Pull-Up Resistor
If the triggered device needs a LVTTL level trigger above 5 V, and a pull-up resistor ranging between
1 KΩ and 10 KΩ should be added.