Chapter 8 I/O Output
8.1 Select Output Signal
The selectable output signal line may differ by camera models.
Type I and Type III Cameras
Type I and type III cameras has four signal lines (Line 0/1/3/4) that can be set as input or output, and
you can set them as output as shown below.
Steps:
1.
Click Digital IO Control, and select specific line as Line Selector.
2.
Set Strobe as Line Mode.
3.
(Optional) Set Line Format according to actual demands.
Differential stands for the differential signal.
SingleEnded stands for the single-ended signal.
Figure 8-1
Select Output Signal (Type I and Type III Cameras)
Type II Camera
The type II camera has two differential output lines: Line 1, Line 4. You can select output signal as
shown below.
Click Digital IO Control > Line Selector, select Line 1 or Line 4 as Line Selector, and enable Strobe
Enable.