Camera Link Line Scan Camera
·
User Manual
50
Line*N
Triggered
Device
Camera Power
PWR
Camera Power Ground
GND
Hang
Line*P
Triggered Device
Power Ground
Signal Line
R
VCC
Figure 9-9
Single-Ended Output Wiring with Pull-Up Resistor
The voltage of the VCC should be matched with the trigger voltage.
9.5 Input Wiring for Type II Camera
Type II camera receives input signals via Line 0/3 to trigger and acquire images. The inputted
signals include differential signal and single-ended signal.
9.5.1 Differential Singal
The wiring may differ by voltages of differential signal sources.
The voltage of the differential signal source is 5 V.
OUT A
Differential Input Positive
OUT Ã
Differential
Signal
Source
Camera Power
Signal Source Power
PWR
VCC
Camera Power Ground
GND
Differential Input Negative
Signal Source Power Ground
Figure 9-10
5 V Differential Signal Source Outputs Differential Signal
The voltage of the differential signal source is 12 V or 24 V.