Camera Link Line Scan Camera
·
User Manual
99
Parameter
Command
Value
Description
ColorTransformationValu
e
selected Gain factor or
Offset inside the
Transformation matrix.
HueAbsVal
w HueAbsVal x
x: 0-255
Set hue. E.g., w HueAbsVal
128.
r HueAbsVal
Read hue.
HueCtrl
w HueCtrl x
x:
0—Off
1—0x1000000
Enable hue or not. E.g., w
HueCtrl 0x1000000.
r HueCtrl
Read enable status of hue.
SaturationAbsVal
w SaturationAbsVal x
x: 0-255
Set saturation. E.g., w
SaturationAbsVal 128.
r SaturationAbsVal
Read saturation.
SaturationCtrl
w SaturationCtrl
x:
0—Off
1—0x10000
Enable saturation or not.
E.g., w SaturationCtrl
0x10000.
r SaturationCtrl
Read enable status of
saturation.
LUTEnable
w LUTEnable x
x:
0—Off
1—On
Activate selected LUT.
E.g., w LUTEnable 1
r LUTEnable
LUTSelector
w LUTSelector x
x:
0—Luminance1
1—Luminance2
2—Luminance3
Select LUT. E.g., w
LUTSelector 0.
r LUTSelector
LUTValue
w LUTValue x
y: desired value
x=y
Returns the Value at entry
LUTIndex of the LUT
selected by LUTSelector.
E.g., Set 100, w LUTValue
262244.
r LUTValue