Camera Link Line Scan Camera
·
User Manual
100
Parameter
Command
Value
Description
LUTSave
w LUT Save x
x:
1—save
Save selected LUT. E.g., w
LUT Save 1
Encoder Source A
w EncoderSourceA x
x:
0—Line0
3—Line3
Set encoder source A. Eg:
w EncoderSourceA 3.
r EncoderSourceA
Read encoder source A.
Encoder Source B
w EncoderSourceB x
x:
0—Line0
3—Line3
Set encoder source B. Eg:
w EncoderSourceB 0.
r EncoderSourceB
Read encoder source B.
EncoderOutputMod
e
w EncoderOutputMode x x:
0—AnyDirection
3—ForwardOnly
Set encoder’s trigger
mode. E.g., w
EncoderOutputMode 1
r EncoderOutputMode
Read encoder’s trigger
mode.
Encoder Counter
Mode
w EncoderCounterMode
x
x:
0—IgnoreDirection
1—FollowDirection
Set encoder counter
mode. Eg: w
EncoderCounterMode 1.
r EncoderCounterMode
Read encoder counter
mode.
Encoder Counter
r EncoderCounter
Read encoder counter.
Encoder Counter
Max
w EncoderCounterMax x
x: 0-32767
Set encoder max. counter.
Eg: w EncoderCounterMax
1.
r EncoderCounterMax
Read encoder max
counter.
Encoder Counter
Reset
w EncoderCounterReset
x
x: 1
Reset encoder counter.
Eg: w
EncoderCounterReset 1.
Encoder Max
Reverse Counter
w
EncoderMaxReverseCou
nter x
x: 0-32767
Set encoder max. reverse
counter. Eg: w
EncoderMaxReverseCount