Camera Link Line Scan Camera
·
User Manual
94
Parameter
Command
Value
Description
TriggerSource
w Trigge6 x
X:
7—software (frame
trigger supported
only)
0—Line0
1—Line1
3—Line3
5—Line4
6—EncoderModuleOu
t
(line
trigger
supported only)
8—FrequencyConvert
er
9—CC1
11—CC2
12—CC3
13—CC4
25—anyway
Set the frame trigger
source
E.g., w Trigge6 7.
w Trigge9 x
Set the line trigger source
E.g., w Trigge9 3.
r Trigge6
Read the frame trigger
source.
r Trigge9
Read the line trigger
source.
TriggerActivation
w TriggerAct6
0—Rising edge
1—Falling edge
Set rising trigger edge. Eg:
w TriggerAct6 0.
r TriggerAct6
0—Rising edge
1—Falling edge
Read trigger edge setting.
TriggerDelay
w TriggerDela6
Value
Set trigger delay. Eg: w
TriggerDela6 100.
r TriggerDela6
Read trigger delay time.
TriggerSoftware
w TriggerSoftware
6
Software trigger once. Eg:
w TriggerSoftware 6.
TriggerCacheEnable
w TriggerCacheEnable x
X:
0—Off
Enable trigger cache or
not. E.g., w
TriggerCacheEnable 65.