Camera Link Line Scan Camera
·
User Manual
101
Parameter
Command
Value
Description
er 1.
r
EncoderMaxReverseCou
nter
Read encoder max.
reverse counter.
Encoder Reverse
Counter Reset
w
EncoderReverseCounterR
eset x
x: 1
Reset encoder reverse
counter. Eg: w
EncoderReverseCounterRe
set 1.
Input Source
w InputSource x
x:
0—Line0
3—Line3
7—EncoderModuleOu
t
Set input source.
Eg: w InputSource 7.
r InputSource
Read input source.
Signal Alignment
w SignalAlignment x
x:
0—RisingEdge
1—FallingEdge
Set signal alignment. Eg: w
SignalAlignment 1.
r SignalAlignment
Read signal alignment.
Trigger Line Rate
(Hz)
r TriggerLineRate
It refers to the external
trigger raw line rate after
filtering.
PreDivider
w PreDivider x
x: 1-128
Set PreDivider. Eg: w
PreDivider 1.
r PreDivider
Read PreDivider.
Multiplier
w Multiplier x
x: 1-32
Set Multiplier.
Eg: w Multiplier 1.
r Multiplier
Read Multiplier.
PostDivider
w PostDivider x
x: 1-128
Set PostDivider. Eg: w
PostDivider 1.
r PostDivider
Read PostDivider.