Camera Link Line Scan Camera
·
User Manual
96
Parameter
Command
Value
Description
1—enable
FrameTimeoutEnable 0.
r FrameTimeoutEnable
Read frame timeout
enable.
AbnormalLineEnabl
e
w AbnormalLineEnable 1 0—disable
1—enable
Enable abnormal line
function.
PreampGain
w PreampGain x
X:
Gain multiple value x
1000
Set gain value.
E.g., w PreampGain 2700
(set the gain as 2.7 x)
r PreampGain
Read gain value.
DigitalShift (Enable)
w DigitalShift y or z
x: the value you want
to set
y: write serial port
value and disable
digital shift
z: write serial port
value and enable
digital shift
y=x × 511 /6 +511
z=x × 511/6+66047
Set digital shift (enable).
Note: the range of digital
shift is -6 to 6.
E.g., w DigitalShift 512. It
means setting gain as
0.01, and disabling digital
shift.
E.g., w DigitalShift 66048.
It means setting gain as
0.01, and enabling digital
shift.
r DigitalShift
When value is larger
than 65536, digital
shift is enabled.
Read digital shift.
If digital shift is enabled,
read z and x =(z-66047) ×
6/511.
If digital shift is disabled,
read y, and x=y × 6/511-6.
BalanceWhiteAuto
w BalanceWhiteAuto
0—off
1—continue
2—once
Set white balance mode.
Eg: w BalanceWhiteAuto
2.
r BalanceWhiteAuto
0—off
1—continue
2—once
Read white balance mode.
BlackLevel
w BlackLevel x
x: 0-4095
Set black level. E.g., w
BlackLevel 5.