Camera Link Line Scan Camera
·
User Manual
106
Parameter
Command
Value
Description
Bit[25]: line5 output
Bit[26]: line8 output
Bit[27]: line11 output
LineSource
w Lin x y
x:
1—Line1
3—Line3
4—Line4
y:
0—ExposureStartActiv
e
5—SoftTriggerActive
6—HardTriggerActive
Selects which internal
acquisition or I/O source
signal to output on the
selected Line.
r Lin x
Read internal acquisition
or I/O source signal to
output on the selected
Line.
LineStrobe
w LineStrobe
0—disable all
2—enable Line1 only
8—enable Line4 only
Enable Line1 or Line4.
Eg: w LineInverter 2
(enable Line1’s inverter).
r LineStrobe
Read LineStrobe status.
StrobeSourceSelect
or
w StrobeSourceS
x y
x:
1—Line1
3—Line3
4—Line4
y:
0—LineMode
2—FrameMode
Select strobe source
according to the trigger
method. E.g., w
StrobeSourceS1 0.
r StrobeSourceS
x
Read strobe source.
StrobeLineDuration
w StrobeLineD x
y
x: 3—Line3
y: 0—10000
Set the duration of strobe,
and the unit is μs. E.g., w
StrobeLineDu3
100.
r StrobeLineD x
Read the duration of
strobe.
StrobeLineDelay
w StrobeLi x y
x: 3—Line3
Set the delay of strobe,