Camera Link Line Scan Camera
·
User Manual
92
Parameter
Command
Value
Description
16—GradualMonoBar
r TestPattern
Read test pattern.
Binning
w Binning X
0x20004 (2 stands for
vertical and 4 stands
for horizontal)
Read combined pixel
number.
r Binning X
Set combined pixel
number. E.g., w Binning
0x20002.
TDIMode
w TDIMode x
x:
0—Line 1
1—TDI_2
SetTDI mode. E.g., w
TDIMode 0.
r TDIMode
Read TDI mode.
AcquisitionBurstFra
meCount
AcquisitionBurstFrameCo
unt x
E.g., w
AcquisitionBurstFrameCou
nt 100
r
AcquisitionBurstFrameCo
unt
Number of frames to
acquire for each
FrameBurstStart trigger.
AcquisitionLineRate
(ControlEnable)
w AcquisitionLineRate x
or y
x: it refers to the
written line rate value
and enable line rate
y: it refers to the line
rate value you want
to set (you can write
directly, and disable
line rate when
writing)
x=y+1073741824
Set line rate (enable).
E.g., w
AcquisitionLineRate
1073841824, it means
setting line rate as
100000, and enabling line
rate.
E.g., w
AcquisitionLineRate
100000, it means setting
line rate as 100000, and
disabling line rate.
r AcquisitionLineRate
When value is larger
than 10737441824,
line rate is enabled
Read line rate:
If line rate is enabled, you
reading and writing x are
available, and line rate is
y=x-1073741824.
If line rate is disabled, the
reading value is y.