9
Menu navigation and adjustment values
46
Term
Description
Unit
Overview Operation
modes
Selection operation modes:
▪
Heating OFF
The heating system is switched off
▪
Heating time mode:
Heating corresponds to the set heating time
▪
Durable heat:
Constant heat up to required set room temperature or to the
calculated feed flow target temperature
▪
Durable kneeling:
Always heat to the kneeling temperature or during the kneeling time
to the calculated flow must temperature
▪
Remote control mode:
Mode according to the setting of the remote control
Menu "Status"
Status 1
1
2
Flow temperature
Indicates the flow temperature of chosen heating circuit
°C
Back flow temperature
Indicates the back flow temperature of chosen heating circuit
°C
Outside temperature
Display of the actual outside temperature
°C
Room temperature
Setting up required room temperature (15-30).
°C
Room correction
The correction is a factor for influencing or correction of the flow must
temperature:
This value (-5 to +5) gets multiplied by 2 and added to the flow set
temperature
°C
Status 2
1
2
Switching temperature
Indicates the switching temperature (= average daytime temperature). In
general, the switching temperature conduces to switch between winter
set temperature and summer set temperature.
°C
Heating circuit mixer
Indicates the state of the heating circuit mixer (OPEN/CLOSE)
-
Heating circuit pump
Indicates the state of the heating circuit pump (ON/OFF)
-
Screed days
Display of the respective screed day (only if screed drying is set)
-
Menu "Settings"
Settings 1
1
2 3
Operation modes
▪
OFF
: The heating system is switched off
▪
Heating time mode
: Heating corresponds to the set heating time
▪
Durable heat
: Constant heat up to required set room temperature or to
the calculated feed flow target temperature.
▪
Durable kneeling
: Always heat to the kneeling temperature or during
the kneeling time to the calculated flow must temperature.
▪
Flow fixed
: During the set heating times the set flow fixed temperature
is kept constant.
▪
Remote control
: Mode according to the setting of the remote control.
▪
Screed drying
: Mode of screed drying. The operation of the screed
drying is described below
-
Summary of Contents for pelletfire 20/20
Page 1: ...OPERATING INSTRUCTIONS Log wood pellet heating system pelletfire 20 40 ...
Page 90: ...15 Annex 90 15 ANNEX 15 1 Additional boiler module Hydraulic recommendation 1 ...
Page 91: ...Annex 15 91 Hydraulic recommendation 2 ...
Page 92: ...15 Annex 92 15 2 Solar module Program 1 ...
Page 93: ...Annex 15 93 Program 2 ...
Page 94: ...15 Annex 94 Program 3 ...
Page 95: ...Annex 15 95 Program 4 ...
Page 96: ...15 Annex 96 Program 5 ...
Page 97: ...Annex 15 97 Program 6 ...
Page 98: ...16 Notes 98 16 NOTES ...
Page 99: ...Notes 16 99 ...