9
Menu navigation and adjustment values
48
Term
Description
Unit
Time 1
1 - 3 times can be set. The second and third time can be added by the +.
Example:
▪
time 1:
08:00
– 10:00
▪
time 2:
15:00
– 21:00
▪
time 3:
00:00
– 00:00
-
08:00
– 11:00
Setting up individual hot water tank loading times of every weekday
-
By pressing the symbol Monday preset gets assigned to remaining
weekdays
-
Barrier times
4 5
Time 1
1 - 2 times can be set. The second time can be added by the +. Example:
see time program.
-
08:00
– 11:00
Setting up individual hot water tank loading times of every weekday,
when it will be not heated
-
By pressing the symbol Monday preset gets assigned to remaining
weekdays.
-
Menu "Heat curve"
Heat curve 1
1
2
Heat curve
-
Heat curve 2
1
2
Flow max.
temperature
Setting up the maximum flow temperature (30-95) of chosen heating
circuit
°C
Root point
temperature
Setting up the minimum flow temperature (20-70) of chosen heating
circuit
°C
Flow temperature at
+10°C
Setting up the flow temperature (20-90) of chosen heating circuit at
+10°C outside temperature
°C
Flow set temperature
at adjustable outside
temperature
Setting up the flow temperature (25-95) of chosen heating circuit at an
adjustable outside temperature
°C
Adjustable outside
temperature
Setting up the outside temperature (-20 - 0) of chosen heating circuit
regarding flow must temperature
°C
Switch off temperature
Setting up the outside temperature (5-40) at which the chosen heating
circuit switches off if this temperature is exceeded.
°C
Operation mode „Screed drying“
After „Screed drying“ mode selection the shown flow temperature sequence (see 9.1 ) gets started
immediately. If a lower flow temperature is desired, the flow temperature can be set up with the parameter
„Flow max. temperature“. If screed drying is interrupted caused by a fault (power breakdown, etc.), the
program (after fault correction) continues drying as shown in 9.1 automatically. An optional continuing day
can be selected with parameter „Screed days“. After screed drying completion the boiler will switch to
"heating time mode". The desired temperature can be set for each day (end of the program with setpoint=
0°C).
Summary of Contents for pelletfire 20/20
Page 1: ...OPERATING INSTRUCTIONS Log wood pellet heating system pelletfire 20 40 ...
Page 90: ...15 Annex 90 15 ANNEX 15 1 Additional boiler module Hydraulic recommendation 1 ...
Page 91: ...Annex 15 91 Hydraulic recommendation 2 ...