9
Menu navigation and adjustment values
40
Term
Description
Unit
Additional input
Indicates the state of the additional input.
▪
If the indicator lamp lights up, the additional input is active (there is an
error)
At the additional input, the message of an external unit (CO detector,
extinguishing water tank, system pressure monitoring, etc.) can be
detected, for example.
-
Door open
Indicates the input of the door. If the indicator lamp lights up, the door is
open
-
Menu
„Operating hours“
Operating hours
Pellet operation
1
2 3
Nominal load
Displays system operation hours during nominal load phase (95 -100%)
h
Modulation
Displays system operation hours during modulation phase (94-31%)
h
Part load
Displays system operation hours during part load phase (<30%)
h
Scorch- /burn out
Displays system operation hours during burning, born down and burnout
phase
h
Boiler run time
Displays the boiler run time (=sum of nominal load-, modulation-, part
load- and burn down- /burn out phase)
h
Total
Display of the total operation hours of the system
(incl. Ready)
h
Operating hours
Log wood operation
1
2
3
Nominal load
Displays system operation hours during nominal load phase (95 -100%)
h
Modulation
Displays system operation hours during modulation phase (94-31%)
h
Part load
Displays system operation hours during part load phase (<30%)
h
Scorch- /burn out
Displays system operation hours during burning, born down and burnout
phase
h
Boiler run time
Displays the boiler run time (=sum of nominal load-, modulation-, part
load- and burn down- /burn out phase)
h
Total
Display of the total operation hours of the system
(incl. Ready)
h
Operating hours
1 2
3
Operating hours until
inspection
Display Operating hours until inspection. Can be reset by entering a code.
Information message "Maintenance" (error No.38) appears after the set
inspection interval has been exceeded (standard: 1000 operating hours).
h
Maintenance interval
date:
Display date until to next maintenance.
Information message "Service" (Error No. 39 ) appears after exceeding
the set maintenance interval (standard: 3000 operating hours) or after
exceeding the annual interval.
-
Maintenance interval
remaining - operating
hours:
Display remaining-operating hours until to next maintenance
h
Interval ash tray
Display of the interval (emptying) of the ash tray
h
Interval ash tray actual
Display of the actual interval since the last emptying of the ash tray
h
Summary of Contents for pelletfire 20/20
Page 1: ...OPERATING INSTRUCTIONS Log wood pellet heating system pelletfire 20 40 ...
Page 90: ...15 Annex 90 15 ANNEX 15 1 Additional boiler module Hydraulic recommendation 1 ...
Page 91: ...Annex 15 91 Hydraulic recommendation 2 ...
Page 92: ...15 Annex 92 15 2 Solar module Program 1 ...
Page 93: ...Annex 15 93 Program 2 ...
Page 94: ...15 Annex 94 Program 3 ...
Page 95: ...Annex 15 95 Program 4 ...
Page 96: ...15 Annex 96 Program 5 ...
Page 97: ...Annex 15 97 Program 6 ...
Page 98: ...16 Notes 98 16 NOTES ...
Page 99: ...Notes 16 99 ...