Menu navigation and adjustment values
9
51
9.13.6
Solar
NOTE: At the solar module 5 resp. 6 (only at external solar module) program numbers are available, which
are set up by the service technician. The only differences of the programs are the integration and the number
of tanks (e.g. hot water tank, buffer). The hydraulic schemes of the different modules are described in
appendix 15.2.
Navigation:
→
→
SOLAR
Screen:
By pressing the button:
the „Solar status“ menu will be displayed
the menu for the "settings" will be displayed
the menu for the "Aggregate-
Test“ will be displayed
the „solar yield“ menu will be displayed
Term
Description
Unit
Menu "Status"
Status 1
1
Collector flow
temperature
Indicates the collector flow temperature
°C
Collector back flow
temperature
Indicates the collector backflow temperature
°C
Tank 1 temperature
Indicates the temperature of tank 1
(e.g.: hot water tank, buffer)
°C
Tank 2 temperature
Indicates the temperature of tank 2
(e.g.: hot water tank, buffer) (only visible, if program 3, 4, 5 or 6 is
chosen)
°C
Collector pump
Indicates the status of the collector pump (On/Off)
-
Loading pump
Displays the condition of the backflow pump (On/Off)
-
Menu "Settings"
Settings
1
Pump trigger
Setting up the minimum collector temperature (15-70) to startup the solar
pump
°C
Summary of Contents for pelletfire 20/20
Page 1: ...OPERATING INSTRUCTIONS Log wood pellet heating system pelletfire 20 40 ...
Page 90: ...15 Annex 90 15 ANNEX 15 1 Additional boiler module Hydraulic recommendation 1 ...
Page 91: ...Annex 15 91 Hydraulic recommendation 2 ...
Page 92: ...15 Annex 92 15 2 Solar module Program 1 ...
Page 93: ...Annex 15 93 Program 2 ...
Page 94: ...15 Annex 94 Program 3 ...
Page 95: ...Annex 15 95 Program 4 ...
Page 96: ...15 Annex 96 Program 5 ...
Page 97: ...Annex 15 97 Program 6 ...
Page 98: ...16 Notes 98 16 NOTES ...
Page 99: ...Notes 16 99 ...