Menu navigation and adjustment values
9
47
Term
Description
Unit
Active Heating time
mode
Indicates the actual operating mode
-
Remote control
number
Display of the selected remote controller
-
Balancing room
sensor
Setting the value (-5 to +5) for calibrating the room sensor
-
Kneeling barrier over
room temperature
Activates the kneeling barrier over the room temperature
-
Barrier over room
temperature
Activates the barrier over the room temperature
-
Settings 2
1
2
3
Room set temperature
Setting up required room temperature (15-30).
°C
Kneeling temperature
Setting up required room temperature (10-22) during lowering time.
°C
Flow fixed
temperature
Setting up the flow temperature (20 to maximum flow set temperature)
during the set heating time (operation mode “flow fixed”)
°C
Room influence
Setting up the factor (0-10) of the room temperature influence.
-
Correction
The correction is a factor for influencing or correction of the flow must
temperature:
▪
This value (-5 to +5) gets multiplied by 2 and added to the flow set
temperature
°C
Kneeling influence
Setting up the factor (0-10) of the kneeling temperature influence.
-
Settings 3
1 2
3
Switching temperature
Setting up the switching temperature (10-35). That´s the average daytime
temperature that conducts the switching between summer mode and
winter mode. The higher the value of the switching temperature is set, the
later the changeover to summer operation is carried out.
°C
Balancing outside
sensor
Adjusting the balancing of the outside temperature sensor (-5 - 5)
▪
Adjustment of the outside temperature sensor to the actual measured
outside temperature (e.g .: with reference thermometer)
°C
Hot water tank priority
Activate hot water tank priority (ON/OFF)
▪
The hot water tank is loaded prior compared to the heating circuit.
-
Kneeling barrier
Activation kneeling barrier (ON/OFF)
▪
The heating circuit is blocked in the case of durable kneeling or outside
the heating time.
-
Menu "Aggregate-Test"
Agg-Test
1
Heating circuit pump*
Indicates the state of the heating circuit pump:
▪
If the indicator lamp lights up, the heating circuit pump is running
-
Heating circuit mixer
OPEN*
Indicates the state of the heating circuit mixer:
If the indicator lamp lights up, the heating circuit mixer is open
-
Heating circuit mixer
CLOSE*
Indicates the state of the heating circuit mixer:
If the indicator lamp lights up, the heating circuit mixer is closed
-
Menu "Time program / Barrier times"
Time program
1 2 3
Summary of Contents for pelletfire 20/20
Page 1: ...OPERATING INSTRUCTIONS Log wood pellet heating system pelletfire 20 40 ...
Page 90: ...15 Annex 90 15 ANNEX 15 1 Additional boiler module Hydraulic recommendation 1 ...
Page 91: ...Annex 15 91 Hydraulic recommendation 2 ...
Page 92: ...15 Annex 92 15 2 Solar module Program 1 ...
Page 93: ...Annex 15 93 Program 2 ...
Page 94: ...15 Annex 94 Program 3 ...
Page 95: ...Annex 15 95 Program 4 ...
Page 96: ...15 Annex 96 Program 5 ...
Page 97: ...Annex 15 97 Program 6 ...
Page 98: ...16 Notes 98 16 NOTES ...
Page 99: ...Notes 16 99 ...