9
Menu navigation and adjustment values
44
Term
Description
Unit
Settings
1
Must temperature
Setting the must temperature (47-85) of the boiler
°C
Min. Temperature
Activate/setting the min. temperature (20-58) (ON/OFF)
▪
With activated min. Outside of the hot water tank loading time, the hot
water tank temperature is set to the set min. temperature loaded.
If the hot water tank temperature is below the value of the set min.
temperature, the hot water tank loading starts.
°C
Min. loading
Indicates/activates the min. loading (20-58) (ON/OFF)
▪
With activated min. Outside of the hot water tank loading time, the hot
water tank temperature is set to the set min.
If hot water tank temperature is lower than the min. loading / temperature
value, the hot water tank loading will start.
°C
Circulation
temperature*
Setting the circulation temperature of hot water tank
°C
Menu "Aggregate-Test"
Agg-Test
1
Hot water tank pump*
If the indicator light lights, the output for controlling of the hot water tank
pump is switched.
Loading valve
If the indicator light lights, the output for controlling of the loading valve is
switched.
Circulation pump
Indicates the state of the hot water tank pump:
If the indicator lamp lights up, the hot water tank pump is activated and
the hot water tank gets charged.
Menu "time program / barrier times / circulation times“
Time program
1 2 3
Time 1
1 - 3 times can be set. The second and third time can be added by the
+. Example:
▪
time 1:
08:00
– 10:00
▪
time 2:
15:00
– 21:00
▪
time 3:
00:00
– 00:00
-
08:00
– 11:00
Setting up individual hot water tank loading times of every weekday
-
By pressing the symbol Monday preset gets assigned to remaining
weekdays
-
Barrier times
4 5
Time 1
1 - 2 times can be set. The second time can be added by the +.
Example: see time program
-
08:00
– 11:00
Setting up individual hot water tank loading times of every weekday,
when it will be not heated
-
By pressing the symbol Monday preset gets assigned to remaining
weekdays.
-
Circulation time
6 7 8
Time 1
1 - 3 times can be set. The second time can be added by the +.
Example: see time program
-
08:00
– 11:00
Setting up individual hot water tank loading times of every weekday,
when the hot water tank circulates.
-
By pressing the symbol Monday preset gets assigned to remaining
weekdays.
-
Summary of Contents for pelletfire 20/20
Page 1: ...OPERATING INSTRUCTIONS Log wood pellet heating system pelletfire 20 40 ...
Page 90: ...15 Annex 90 15 ANNEX 15 1 Additional boiler module Hydraulic recommendation 1 ...
Page 91: ...Annex 15 91 Hydraulic recommendation 2 ...
Page 92: ...15 Annex 92 15 2 Solar module Program 1 ...
Page 93: ...Annex 15 93 Program 2 ...
Page 94: ...15 Annex 94 Program 3 ...
Page 95: ...Annex 15 95 Program 4 ...
Page 96: ...15 Annex 96 Program 5 ...
Page 97: ...Annex 15 97 Program 6 ...
Page 98: ...16 Notes 98 16 NOTES ...
Page 99: ...Notes 16 99 ...