LOCATION COMPONENT
FUNCTION/DESCRIPTION
C7
C1
Adjusts the frequency of crystal Y1.
C6
C3
Adjusts the frequency of crystal Y2.
F4
F1
Fuse in +22 Volt unregulated input for +15 Volt and +5 Volt regulators.
G6
F2
Protects -22 Volt supply if a -15 Volt regulator fault occurs.
G2
J2
Input for external frequency source (e.g. AM Stereo Exciter, Combiner Common
Drive). Input level: TTL Level, or 0 to +25 dBm at 50 Ohms.
F1
J3
Input, from “Output Current Sample,” T6, used for Oscillator Sync.
A3
J5
Output for optional Frequency Monitor.
A2
J7
Input/Output connector between LED board and Oscillator. Oscillator Sync control
signal input, RF present output.
E2
L4
Used for fine adjustment of oscillator sync phase.
D6
P1
Selects either crystal Y1 or Y2. For Y1, jumper 1-2; for Y2, jumper 1-3.
A5
P2
Selects the ratio of crystal frequency to transmitter carrier frequency. To divide by 4,
jumper 1-2; to divide by 8, jumper 1-3.
C1
P3
Used to select onboard crystal oscillator (jumper 1-3) or external oscillator (jumper 1-
2).
C1
P4
For normal operation, jumper 2-3. For combined transmitter operation, jumper 1-2.
F2
P5
Selects a 50 Ohm input impedance for external oscillator (jumper 1-3) or 20K Ohm in-
put impedance for TTL input (jumper 1-2).
F7
P6
Selects the crystal oven which will be heated. For Y1 oven, jumper 1-2; for Y2 oven,
jumper 1-3.
E1
S1
Used for coarse adjustment of oscillator sync phase.
B3
TP1
Test point for +15 Volt zener-regulated voltage.
E4
TP2
Test point for +5 Volt zener-regulated voltage.
A2
TP3
Test point for +9 Volt zener-regulated voltage.
D1
TP4
Test point, used during oscillator sync phase adjustment.
D1
TP5
Test point, used during oscillator sync adjustment.
E4
TP6
Used as a test equipment ground connection when making measurements on the oscil-
lator board.
C7
TP7
Used as a test equipment ground connection when making measurements on the Oscil-
lator board.
NOTE
Test points are small wire loops, for connecting clip-on oscilloscope or meter probes.
Table A-2. Oscillator Board A17, Controls and Indicators
DX-25U
A-4
888-2297-002
WARNING: Disconnect primary power prior to servicing.