11-14
Fault/UID LED status
Present/Active LED status
Description
Off Steady
green
The drive is present but no data is being
read or written to the drive.
Off
Off
The drive is not securely installed.
Table 11-5 NVMe drive LED description
Fault/UID LED status
Present/Active LED status
Description
Flashing amber (0.5 Hz)
Off
The managed hot removal process is
completed. You can remove the drive
safely.
Flashing amber (4.0 Hz)
Off
The drive is in hot plug process.
Steady amber
Steady green/Flashing green
(4.0 Hz)
The drive is faulty. Replace the drive
immediately.
Steady blue
Steady green/Flashing green
(4.0 Hz)
The drive is operating correctly and selected
by the RAID controller.
Off
Flashing green (4.0 Hz)
The drive is performing a RAID migration or
rebuilding, or the system is reading or
writing data to the drive.
Off Steady
green
The drive is present but no data is being
read or written to the drive.
Off
Off
The drive is not securely installed.
Drive configurations and numbering
4LFF server
presents the drive configurations available for the 4LFF server and their compatible types
of storage controllers.
Table 11-6 Drive and storage controller configurations (4LFF server)
Drive configuration
Storage controller
4LFF
(4 front LFF SAS/SATA drives)
•
Embedded
RSTe
•
Mezzanine
•
Standard
4LFF+2SFF
(4 front LFF SAS/SATA 2 rear SFF
SAS/SATA drives)
•
Embedded
RSTe
•
Mezzanine
These drive configurations use different drive numbering schemes, as shown in
Table 11-7 Drive numbering schemes (4LFF server)
Drive configuration
Drive numbering
4LFF (4 front LFF drives)
.
4LFF+2SFF (4 front LFF drives and 2 rear SFF drives)
.