1/0 (on/off) via the object Power on/off.
In the IR Split Unit control mode, touch this button and the device will send a corresponding command
message according to the database configuration through the object IR Split unit command.
If the startup mode is heating or cooling mode, only the corresponding temperature control command
message will be sent out. At startup, the corresponding mode, temperature setting, and wind speed will be
displayed according to the database configuration.
②
AC Mode
The heating, cooling, dehumidification, and air supply modes for selecting the air conditioner can be updated
by the object.
③
Wind speed
Touch this icon, and the wind speed will be switched from 1 to 1 AUTO...1 from the current wind speed level.
In the Gateway Integrate control mode, the boot wind speed does not change; in the IR Split Unit control
mode, the boot displays the corresponding wind speed profile according to the configuration.
④
Temperature display
Touch
or
icons, the display can be switched between the room temperature and the outdoor
temperature.
Units can be selected based on the configuration of the database Temperature display units, select Celsius
(°C) or Fahrenheit (°F) to display.
⑤
Set temperature adjustment
The touch icon will be +/- 1°C above the current temperature and send a corresponding message on the
bus.
The adjustment range for setting the temperature is limited to 16-32°C by default and can be modified by the
database "Min./Max. set temperature [16...32]°C". In the dehumidification and air supply mode, the set
temperature is not adjustable.