121
Appendix
Declar
ation
Spar
e P
ar
ts
Main
tenance
Insta
llation
Technica
l Inf
ormation
Instruc
tions f
or use
pr
oduc
t Description
In
tr
oduc
tion
Con
ten
ts
Oper
ation & Main
tenance Manual SpeedStile B
P DS
Fig 8.13 – MB01 Jumpers
JUMPERS
W1
IN: current limitation threshold at
50% (factory setting: OFF)
W2
NC/NO contact configuration of K2
relay (factory setting: NO)
W3
NC/NO contact configuration of K1
relay (factory setting: NO)
W4
NC/NO contact configuration of K3
relay (factory setting: NO)
W5
NC/NO contact configuration of K4
relay (factory setting: NO)
W6
IN: RS485 line termination
(factory setting: OFF)
W7
IN: CAN bus line termination
(factory setting: OFF)
W8
IN: CAN bus line termination
(factory setting: OFF)
COPPER JUMPERS
B1
and
B2
Traffic light, green symbol output
configuration.
NPN: B1 in, B2 off; PNP: B1 off, B2 in
(factory setting: NPN)
B3
and
B4
Traffic light, red symbol output
configuration.
NPN: B3 off, B4 in; PNP: B3 in, B4 off
(factory setting: NPN)
B5
and
B6
Pictogram, green symbol output
configuration.
NPN: B5 in, B6 off; PNP: B5 off, B6 in
(factory setting: NPN)
B7
and
B8
Pictogram, badge symbol output
configuration.
NPN: B7 off, B8 in; PNP: B7 in, B8 off
(factory setting: NPN)
B9
and
B10
Pictogram, badge symbol output
configuration.
NPN: B9 off, B10 in; PNP: B9 in, B10
off (factory setting: NPN)
B12
IN: redundant protection active
(factory setting: IN)