54
In
tr
oduc
tion
Pr
oduc
t Description
Instruc
tions f
or use
Technica
l Inf
ormation
Insta
llation
Main
tenance
Spar
e P
ar
ts
Appendix
Con
ten
ts
Declar
ation
Oper
ation & Main
tenance Manual SpeedStile B
P DS
For example: if a given input is programmed to be “WIDE READER –B-“, when properly signalled,
the stack of Reader B interface will be incremented and any passage in direction B until the stack
reaches zero will be treated as Wide passage.
Output Relays Programming
Introduction
The SpeedStile BP DS provides a total of 15 programmable relays:
7 on the Control board (K1 : K7) CG01,
4 relays each on the Motor boards (K1 : K4) MB01.
These relays can be set as Normally Closed or Normally Open through jumpers and programmed
to be addressed to a set of flags through a logical mask.
Flags
The system flags are a number of Boolean events collected by the Gate Controller which
represents the state of the gate. Follows a table showing the whole set of flags and their meaning.
System Flags Reference
Flags
Meaning
Reader A Enable:
Signals when the logic is ready to accept
authorisations from the reader in A direction
Reader B Enable:
Signals when the logic is ready to accept
authorisations from the reader in B direction
Ack Count A:
Pulse to acknowledge that a person passed the
gate in direction A
Ack Count B:
Pulse to acknowledge that a person passed the
gate in direction B
Gate Busy A:
Signals that the gate engaged in direction A
Gate Busy B:
Signals that the gate engaged in direction B
Door Closed:
Signals that the doors are in closed position
Door Opened:
Signals that the doors are in open position
Out Of Service:
Signals a technical alarm, fault of part of
the system, power failure, gate unavailable
because operating the start up checks.
Emergency:
Signals that the Emergency command is being
executed
Ack Reader A:
Pulse to acknowledge the reader A that the
authorisation was received.
Ack Reader B:
Pulse to acknowledge the reader B that the
authorisation was received
Power Failure
If the gate is equipped of battery, signals that
the power failed
Fraud_Tail_A:
Signals when the logic detects a Tailgating in
the direction A
Fraud_Tail_B:
Signals when the logic detects a Tailgating in
the direction B
Fraud_Intr_A:
Signals when the logic detects an Intrusion in
the direction A