Interface Inputs and Outputs
The SpeedStile BP DS provide twelve inputs each one programmable to be ad-dressed to one of
the Reader's triggers.
To obtain the most flexible signals, interface from the SpeedStile BP DS toward the ticket
readers and surrounding systems. The logic offers a wide set, of electric inputs and outputs.
A logic function attributed to each one of these can be set with values on corresponding
programmable parameters (see “I/O Group” in the annex “Parameter Table”).
All the outputs are dry contact relays, NC/NO configurable by jumpers (30 V max; 0.5 A max)
Fig 4.14 – GC01 Addressable Inputs (M5 - M6) and Outputs (M3 – M7)