Events involved in a Controlled Access
Fig 4.11 – Validation Process in CONTROLLED Mode
Dir.A
>>
>>
X
X
The User approaching the gate validates the ticket to get the permission and the validation
should be made in the Zone 1.
The Tracer LED and casework LEDs acknowledges the event showing a green for a while (timed
or position dependent). The User gains immediately the Priority and the doors open whether the
user is inside or outside of the aisle.
Flags
Value
Reader A enable
0
Reader B enable
x
Ack count A
0
Ack count B
0
Gate Busy A
1
Gate Busy B
0
Door closed
0
Door open
1
Gate alarm
0
Out of service
0
Emergency
0
Ack reader A
Pulse
Ack reader B
0
Power fail