72
In
tr
oduc
tion
Pr
oduc
t Description
Instruc
tions f
or use
Technica
l Inf
ormation
Insta
llation
Main
tenance
Spar
e P
ar
ts
Appendix
Con
ten
ts
Declar
ation
Oper
ation & Main
tenance Manual SpeedStile B
P DS
Open / Close test
Path:
Main menu / Maintenance / Open-Close test
The display will show:
C L C L C L
A L L M A S T E R S L A V E
SW1
SW2
SW3
RESET
CL: closed.
OP: open.
ND:
moving or not defined status.
The open or close command can be given to each door by pressing the corresponding button:
SW1
For both doors.
SW2
For master door.
SW3
For slave door.
A buzzer beep signals any new command given.
If the safety area is obscured or the closing is blocked, the motion will not start (see section
“Safety Photocells Management”).
Press the Esc key combination to exit the test; the doors remain in their last selected position.
Repeated Open/Close Cycle
Path:
Main menu / Maintenance / Repeated Open/Close test
C N : 0
S T A R T C L R S T O P
SW1
SW2
SW3
RESET
Pushing button
SW1
the cycle will start; it is stopped by pushing button
SW3
.
The sequence is composed of the alternative opening and closing of the two doors. During these
cycles, the obstacle detection is active. On the upper row of the display, the counting of the open/
close sequence (CN) is displayed. By pushing button
SW2
, the counter is cleared
Battery Test
Path:
Main menu / Maintenance / Battery test
The Battery Maintenance menu allows the monitoring of the actual status of the installed
battery back-up cells if enabled. The tool allows reading of the batteries charge level and gives