Figure 4.6 – Example of Zones Configuration
1
2
3
4
5
6
If “Access Level”, for example, is programmed as “4”:
•
Zone 1- sensor 1, 2 and 3.
•
Zone 2- no sensors.
•
Tailgating disabled.
If the doors are closed and passenger engages the Zone 1/2 sensors and the Zone 1/2 time
out elapses, the Control Logic signals an intrusion and the display flashes; but the buzzer doesn’t
sound.
If the doors are open,and the passenger engages the Zone 1 sensors and the Zone 1 time-out
elapses, the buzzer sounds.
If the doors are open,and the passenger engages the Zone 2 sensors, the buzzer sounds
immediately.
Zone timet and operation modality are set-table by means of the programmable parameters of
the “Reader Group” (see the annex “Parameter Table”).