71
Appendix
Declar
ation
Spar
e P
ar
ts
Main
tenance
Insta
llation
Technica
l Inf
ormation
Instruc
tions f
or use
pr
oduc
t Description
In
tr
oduc
tion
Con
ten
ts
Oper
ation & Main
tenance Manual SpeedStile B
P DS
Board
Message
Description
CB
Obscured sensor
One of the passage detection system sensors
engaged for more than a fixed time
Check the View aisle menu to confirm sensor.
Sensors not engaged
One or more sensors weren't obscured as expected
after a transit.
On/off test fail
The safety sensor test has failed.
Master disconnected
Error in the communication via CAN bus between
GC01 and MB01 master.
Slave disconnected
Error in the communication via CAN bus between
GC01 and MB01 slave.
MS/SL:
Supervisor
The “Supervisor circuit” has stopped the motor.
Encoder fail
Failure of the mechanism position device.
Run fail
The open/close command was not completed
within 15 seconds.
Obstacle fail
The control board signals four consecutive
obstacles and the door movement isn't completed.
Out of target
The reed sensor signals a door movement while
the door should be in the target position.
Power fault
The main power was off for a time greater than
a value and the Motor Board shut-downs the
electronic.
Power warning
The main power was off for a time greater than
500 ms and starts the timer for the shutdown.
Battery fault
The battery charge is less than the 78% of the
main charge.
Test. Superv.
On start-up, the MB01 makes a test on the
“Supervisor Circuit”. If this test fails, it’s displayed
a fault message.
Maintenance Menu
From this menu, the following utilities are available for devices tests:
•
Open/close test of the door.
•
Repeated open/close cycle.
•
Battery test.
•
Buzzer test.
•
Traffic lights and pictograms test.
•
Safety sensor test.
•
Real time photocells test.
•
Striped photocells test.
•
Relay outputs test.