Note:
When collecting data with the horn antennas, positioning the direct coupling correctly in the time
range window is critical. If the scan is positioned incorrectly, the RADAN 7 ™ data processing functions
will not work correctly. The signal position cannot be corrected after it has been collected.
Figure 102: Signal Position Auto. Range displayed 19 ns.
f)
Select RADAR CONFIG > SCAN. Set the POSITION MODE to Manual.
Figure 103: Surface Mode - Manual. Range displayed = 19 ns.
g)
Set the SURFACE (%) to 0.00.