English (GB)
35
00418
Pump1Current
0.1 A
Motor current.
00419
Pump1LatestCurrent
0.1 A
Latest motor current.
00420
Pump1Voltage
0.1 V
Voltage.
00421
Pump1Insulation
10 k
Ω
Motor insulation resistance.
00422
Pump1WaterInOil
0.1 %
Motor water-in-oil measurement.
00423
Pump1Alarms1
Bits
See section
00424
Pump1Alarms2
Bits
See section
00425
Pump1Alarms3
Bits
See section
00426
Pump1Warnings1
Bits
See section
00427
Pump1Warnings2
Bits
See section
00428
Pump1Warnings3
Bits
See section
00429
Pump1MotorTemperature1
1 °C
Motor temperature 1.
00430
Pump1MotorTemperature2
1 °C
Motor temperature 2.
00431
Pump1PowerHI
1 W
Power consumption.
00432
Pump1PowerLO
00433
Pump1EnergyHI
0.1 kWh
Energy consumption.
00434
Pump1EnergyLO
00435
Pump1CosPhi
0.01
Motor cos
φ
.
00436
Pump1Frequency
0.1 Hz
Motor-applied frequency.
00437
Pump1VFDmode
enum
Mode of variable-frequency drive.
0 = VFD not controlled
1 = -
2 = Stopped
3 = Reverse start
4 = Start flushing
5 = Normal
6 = Run flushing
7 = Stop flushing
8 = Specific-energy test.
00438
Pump1Torque
0.1 Nm
Motor torque.
00439
Pump1iAsym
0.1 %
Line current asymmetry.
00440
Pump1Sensors.WIO
Bit 0: WaterInOilSensor
Bool
Presence of water-in-oil (WIO) sensor.
0 = Not present
1 = Present.
Pump1Sensors.Current
Bit 1: MotorCurrentSensor
Bool
Presence of current sensor.
0 = Not present
1 = Present.
00441
Pump1Alarms4
Bits
See section
00442
Pump1Warnings4
Bits
See section
00443
Pump1AntiBlockingCounter
Bits
Number of anti blockings in the pump
00444
Pump1AISetpointSelect
enum
Analog input used as setpoint for pump 1:
13 = User defined sensor 1
14 = User defined sensor 2
15 = User defined sensor 3
00445
Pump1SetpointType
enum
Setpoint type for pump 1:
0 = Fixed value
1 = Analog input
00446
Pump1FeedbackSensorType
enum
Feedback sensor type for pump 1:
4 = Flow rate
5 = Level, pressure
6 = Level, Ultrasound
13 = User defined sensor 1
14 = User defined sensor 2
15 = User defined sensor 3
00447
Pump1ControlMode
enum
Control mode for pump 1:
0 = Fixed frequency
1 = Linear control
2 = Minimum control
3 = PID control
00448
Pump1ActualSetpoint
1 %
Actual setpoint for pump 1
00449
Pump1FixedFrequency
0.01 Hz
Fixed frequency for pump 1
Address
Register name
Scale
Description
Pumpland.ru
Summary of Contents for CIM 200