Installation and operating manual
G932.1 - 06/2010
EN-19
EN
EN
Adjusting the start override
–
Load the load raising equipment with the nominal load.
–
Raise the nominal load from the ground.
–
Turn the lower controller (2) to the left to the limit.
–
Press the UP button.
The hoist must stop immediately.
Note:
Briefly press the DOWN button every time after stopping the
hoist during this setting procedure in order to re-enable the rais-
ing movement.
–
Turn the lower controller (2) slightly to the right.
–
Press the UP button.
–
Repeat the procedure until it becomes possible to raise the
nominal load.
–
Seal both controllers with sealing wax.
15.6
Ordering spare parts
Spare parts lists can be requested from your supplier or directly
from Greifzug Hebezeugbau GmbH.
The necessary information for placing the order is located on the
nameplates of the individual components, see Fig. 10. Replace
missing or illegible labels immediately.
Rope drive:
Article no., tirak™ model, rope diameter, serial number
Motor:
Article no., Motor model
Brakes:
Article no., Type and coil voltage of the brake
Electrical controls:
Number of the circuit diagram
16
Disposal and environmental
protection
The equipment is made from recyclable materials. If the equip-
ment is later scrapped, it must be disposed off correctly. The
national versions of the waste legislation directive 75/442/EEC
apply within the European Union (in Germany Kreislauf-
wirtschafts- und Abfallgesetz (KrWAbfG)).
The manufacturer is obliged to take back and dispose of specific
electrical and electronic components in accordance with Directive
2002/96/EC. The following symbol is used on the nameplate of
such components to identify them: