118
Trinix NXT — Installation and Service Manual
Section 9 — Planning Guide
42 A @ 48 VDC
CASE B: A fully configured system that is operating in boosted
mode.
DV-33128 and NXT-128
13.2 A @ 48 VDC
DV-33256 and NXT-256
26.3 A @ 48 VDC
DV-33512 and NXT- 512
52.5 A @ 48 VDC
TRX-NXT-256x512
23 A @ 48 VDC
TRX-NXT-256x512
44 A @ 48 VDC
TRX-NXT-512x1024
44 A @ 48 VDC
Inrush Current
128 x 128 frame: 15 A
256 x 256 frame: 21 A
512 x 512 frame: Approximately 25 A
128 x 256 frame: 25 A
256 x 512 frame: 25 A
512x1024 frame: 25 A
Alarm
The alarm connector is a BNC type and meets SMPTE 269M-1999.
Environmental
0 to +35 degrees C (+32 to +95 F)
10 to 90%, Non-condensing
Air Flow
The Door should remain closed during operation for all Trinix models.
Requirements for the Trinix 512x1024’s airflow and clearance:
Summary of Contents for TRINIX NXT -
Page 10: ...10 Trinix NXT Installation and Service Manual Preface ...
Page 26: ...26 Trinix NXT Installation and Service Manual Regulatory Notices ...
Page 30: ...30 Trinix NXT Installation and Service Manual ESD Protection ...
Page 120: ...120 Trinix NXT Installation and Service Manual Section 9 Planning Guide ...
Page 284: ...284 Trinix NXT Installation and Service Manual Section 12 Broadlinx Installation ...
Page 336: ...336 Trinix NXT Installation and Service Manual Section 14 Broadlinx Console Commands ...
Page 370: ...370 Trinix NXT Installation and Service Manual Section 16 Protected Paths ...
Page 436: ...436 Trinix NXT Installation and Service Manual Appendix 22 Trinix Frame Slot Maps ...
Page 440: ...440 Trinix NXT Installation and Service Manual Appendix 23 Expanded System Sizes ...