Trinix NXT — Installation and Service Manual
87
Duplication and Expansion
Termination for Pre-wired Expansion Frames
The unused BNC connectors on the port expanders should be terminated
for best performance. However, it may be desirable to install an empty or
partially filled frame with associated cabling to simplify future expansion.
When such cabling connects to a Port expander that is carrying active sig-
nals, special termination hardware is required. Since the presence of pre-
wired cabling will not permit standard BNC terminators to be installed on
the expander, an
LD-33100 Loader board
must be installed in the associ-
ated frame in place of an input or output board to provide correct termina-
tion.
Grass Valley recommends that you terminate all unused outputs that may
be driven with an active signal. Properly shielded 75-ohm terminators or
spare infrastructure coax cables should be used. This step will ensure EMC
compliance. Spare output BNC panels that are not populated with output
boards and spare input BNCs do not need to be terminated.
Figure 45. LD-33100 Loader Board
Input Expansion
For example, the figure below (
shows a 512 x 512 system that has
been expanded to 1024 x 512:
Summary of Contents for TRINIX NXT -
Page 10: ...10 Trinix NXT Installation and Service Manual Preface ...
Page 26: ...26 Trinix NXT Installation and Service Manual Regulatory Notices ...
Page 30: ...30 Trinix NXT Installation and Service Manual ESD Protection ...
Page 120: ...120 Trinix NXT Installation and Service Manual Section 9 Planning Guide ...
Page 284: ...284 Trinix NXT Installation and Service Manual Section 12 Broadlinx Installation ...
Page 336: ...336 Trinix NXT Installation and Service Manual Section 14 Broadlinx Console Commands ...
Page 370: ...370 Trinix NXT Installation and Service Manual Section 16 Protected Paths ...
Page 436: ...436 Trinix NXT Installation and Service Manual Appendix 22 Trinix Frame Slot Maps ...
Page 440: ...440 Trinix NXT Installation and Service Manual Appendix 23 Expanded System Sizes ...