Trinix NXT — Installation and Service Manual
109
LAN and Com Bus Connections
LAN and Com Bus Connections
The LAN (NIC) connections use a standard 10/100BaseT twisted pair cable
with RJ-45 connectors (Cat 5E Enhanced is recommended). Shielded cable
is also recommended, maximum length 60 meters.
1
The maximum length
for a non-shielded cable is 100 meters.
LAN Monitoring Only (Jupiter Control)
In this arrangement, the router is under Jupiter control. The only purpose
of the connection is LAN monitoring using Broadlinx web pages or SNMP.
See
.
Figure 58. LAN Connections for LAN Monitoring Only (Jupiter Control)
Another Ethernet cable must be connected from the NIC B jack to the
network switch if you plan to use a secondary Broadlinx board.
If the Trinix LAN is connected to the Internet, the connection should be
made through a firewall.
Note
Do not use Broadlinx with either the Dynex DX-ESW8, 10/100M Fast Ethernet
Switch or the Zonet Model ZFS3124.
1.
Compliance with EEC, EMC, EN series, UL- 1950, and CSA C22.2 No. 950-M89 standards requires use of a shielded cable.
NIC A
connector
Ethernet switch
NIC B
connector
Trinix
Monitoring PC
Summary of Contents for TRINIX NXT -
Page 10: ...10 Trinix NXT Installation and Service Manual Preface ...
Page 26: ...26 Trinix NXT Installation and Service Manual Regulatory Notices ...
Page 30: ...30 Trinix NXT Installation and Service Manual ESD Protection ...
Page 120: ...120 Trinix NXT Installation and Service Manual Section 9 Planning Guide ...
Page 284: ...284 Trinix NXT Installation and Service Manual Section 12 Broadlinx Installation ...
Page 336: ...336 Trinix NXT Installation and Service Manual Section 14 Broadlinx Console Commands ...
Page 370: ...370 Trinix NXT Installation and Service Manual Section 16 Protected Paths ...
Page 436: ...436 Trinix NXT Installation and Service Manual Appendix 22 Trinix Frame Slot Maps ...
Page 440: ...440 Trinix NXT Installation and Service Manual Appendix 23 Expanded System Sizes ...